New Technologies for Outcome Measures in Retinal Disease: Review From the European Vision Institute Special Interest Focus Group
Abstract Novel diagnostic tools to measure retinal function and structure are rapidly being developed and introduced into clinical use. Opportunities exist to use these informative and robust measures as endpoints for clinical trials to determine efficacy and to...
Publication: Interspecies Variation of Outer Retina and Choriocapillaris Imaged With Optical Coherence Tomography
Authors: Petr Soukup; Peter Maloca; Bernd Altmann; Matthias Festag; Elke-Astrid Atzpodien; Simon Pot Abstract Purpose: The purpose of this study is to assess with spectral-domain optical coherence tomography (OCT) the interspecies variation of outer retinal...
Publication: Validation of automated artificial intelligence segmentation of optical coherence tomography images
Authors: Peter M. Maloca, Aaron Y. Lee, Emanuel R. de Carvalho, Mali Okada, Katrin Fasler, Irene Leung, Beat Hoermann, Pascal Kaiser, Susanne Suter, Pascal W. Hasler, Javier Zarranz-Ventura, Catherine Egan, Tjebo F. C. HeerenID,Konstantinos Balaskas, Adnan Tufail,...
Publication: RETINAL-CHOROIDAL ANASTOMOSIS IN MACULAR TELANGIECTASIA TYPE 2.
Authors: Spaide RF, Yannuzzi LA, Maloca PM. Retina. 2018 Oct;38(10):1920-1929. doi: 10.1097/IAE.0000000000002289. PURPOSE: To investigate the deep retinal vascular changes potentially present in macular telangiectasis Type 2 (MacTel 2) with projection resolved...
Publication (best clincial study): Interdevice variability of central corneal thickness measurement
Authors: Maloca PM, Studer HP, Ambrósio R Jr, Goldblum D, Rothenbuehler S, Barthelmes D, Zweifel S, Scholl HPN, Balaskas K, Tufail A, Hasler PW Abstract PURPOSE: To evaluate variability of central corneal thickness measurement (CCT) devices using a hitherto...
Publication: Feasibility of support vector machine learning in age-related macular degeneration using small sample yielding sparse optical coherence tomography data
Authors: Quellec G, Kowal J, Hasler PW, Scholl HPN, Zweifel S, Konstantinos B, de Carvalho JER, Heeren T, Egan C, Tufail A, Maloca PM Abstract PURPOSE: A retrospective pilot study is conducted to demonstrate the utility of a novel support vector machine learning...
Publication: Statistical framework for validation without ground truth of choroidal thickness changes detection
Authors: Ronchetti T, Jud C, Maloca PM, Orgül S, Giger AT, Meier C, Scholl HPN, Chun RKM, Liu Q, To CH, Považay B, Cattin PC. Abstract: Monitoring subtle choroidal thickness changes in the human eye delivers insight into the pathogenesis of various ocular diseases...
Publication: High-Resolution In Vivo Fundus Angiography using a Nonadaptive Optics Imaging System
Purpose: We provide a proof of concept for the detailed characterization of retinal capillary features and surrounding photoreceptor mosaic using a customized nonadaptive optics angiography imaging system. Methods: High-resolution fluorescein angiography (FFA) and/or...
Invitation unique IMAX OCT congress_Saturday, 23. November 2019 Luzern
Swiss cheese retina? Ein junger gesunder Patient erschien wegen einem Visus Verlust. Im OCT fand ich ein Macula Ödem ohne Ursache. Kein Diabetes, kein Gefäss Verschluss. Erster Blick! Auf den zweiten Blick zeigten sich einige winzige "Löcher" in seiner Netzhaut und...
Publication: Enhanced resolution and speckle-free three-dimensional printing of macular optical coherence tomography angiography.
PURPOSE: To demonstrate the feasibility of three dimensional (3D) printing of macular Optical Coherence Tomography Angiography (OCTA). METHODS: 9 Nine repeated and tracked OCTA measurements were performed on one healthy eye of a 35 year old emmetropic female with...